<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-14 08-56-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 66 kHz 15782 6,8496
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,4 dBr 4,47 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 66 kHz MIN: 9 kHz % above 76 kHz: 6,8496 Acquired: 2025/05/14 8.55.09 Total samples: 15782 Equivalent time: 0:13:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,2 dBr MIN: 3,4 dBr AVE: 4,47 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/05/14 8.55.09) 08.42 08.44 08.46 08.48 08.50 08.52 08.54 0 2 4 6 Pm [dBr]